仅对英特尔可见 — GUID: mcn1441700913968
Ixiasoft
单端SSTL,HSTL和HSUL I/O标准信号规范
I/O标准 | VIL(DC) (V) | VIH(DC) (V) | VIL(AC) (V) | VIH(AC) (V) | VOL (V) | VOH (V) | IOL 35(mA) | IOH 35 (mA) | ||
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | Min | Max | Max | Min | Max | Min | |||
SSTL-18 Class I | –0.3 | VREF –0.125 | VREF + 0.125 | VCCIO + 0.3 | VREF – 0.25 | VREF + 0.25 | VTT – 0.603 | VTT + 0.603 | 6.7 | –6.7 |
SSTL-18 Class II | –0.3 | VREF –0.125 | VREF + 0.125 | VCCIO + 0.3 | VREF – 0.25 | VREF + 0.25 | 0.28 | VCCIO –0.28 | 13.4 | –13.4 |
SSTL-15 Class I | — | VREF – 0.1 | VREF + 0.1 | — | VREF – 0.175 | VREF + 0.175 | 0.2 × VCCIO | 0.8 × VCCIO | 8 | –8 |
SSTL-15 Class II | — | VREF – 0.1 | VREF + 0.1 | — | VREF – 0.175 | VREF + 0.175 | 0.2 × VCCIO | 0.8 × VCCIO | 16 | –16 |
SSTL-135 | — | VREF – 0.09 | VREF + 0.09 | — | VREF – 0.16 | VREF + 0.16 | 0.2 × VCCIO | 0.8 × VCCIO | — | — |
SSTL-125 | — | VREF – 0.09 | VREF + 0.09 | — | VREF – 0.15 | VREF + 0.15 | 0.2 × VCCIO | 0.8 × VCCIO | — | — |
SSTL-12 | — | VREF – 0.10 | VREF + 0.10 | — | VREF – 0.15 | VREF + 0.15 | 0.2 × VCCIO | 0.8 × VCCIO | — | — |
HSTL-18 Class I | — | VREF –0.1 | VREF + 0.1 | — | VREF – 0.2 | VREF + 0.2 | 0.4 | VCCIO – 0.4 | 8 | –8 |
HSTL-18 Class II | — | VREF – 0.1 | VREF + 0.1 | — | VREF – 0.2 | VREF + 0.2 | 0.4 | VCCIO – 0.4 | 16 | –16 |
HSTL-15 Class I | — | VREF – 0.1 | VREF + 0.1 | — | VREF – 0.2 | VREF + 0.2 | 0.4 | VCCIO – 0.4 | 8 | –8 |
HSTL-15 Class II | — | VREF – 0.1 | VREF + 0.1 | — | VREF – 0.2 | VREF + 0.2 | 0.4 | VCCIO -0.4 | 16 | –16 |
HSTL-12 Class I | –0.15 | VREF – 0.08 | VREF + 0.08 | VCCIO + 0.15 | VREF – 0.15 | VREF + 0.15 | 0.25 × VCCIO | 0.75 × VCCIO | 8 | –8 |
HSTL-12 Class II | –0.15 | VREF – 0.08 | VREF + 0.08 | VCCIO + 0.15 | VREF – 0.15 | VREF + 0.15 | 0.25 × VCCIO | 0.75 × VCCIO | 16 | –16 |
HSUL-12 | — | VREF – 0.13 | VREF + 0.13 | — | VREF – 0.22 | VREF + 0.22 | 0.1 × VCCIO | 0.9 × VCCIO | — | — |
POD12 | –0.15 | VREF – 0.08 | VREF + 0.08 | VCCIO + 0.15 | VREF – 0.15 | VREF + 0.15 | — | — | — | — |
35 要满足IOL和IOH规范,您必须相应地设置电流强度。例如,要满足SSTL15CI规范(8 mA),您应该将电流强度设为8 mA。设成较低的电流强度可能不会满足数据表中的IOL和IOH规范。