文章 ID: 000078286 内容类型: 错误讯息 上次审核日期: 2021 年 08 月 29 日

1000BASE-X/SGMII PCS 功能的关键警告消息

环境

  • 英特尔® Quartus® II 订阅版
  • 以太网
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    关键问题

    说明

    编译包含 1000BASE-X/SGMII PCS 的设计时 函数,Quartus® II 软件显示以下警告 消息:

    Critical Warning: "mixed_port_feed_through_mode" parameter of RAM atom altera_tse_mac_pcs_pma_gige:altera_tse_mac_pcs_pma_gige_inst|altera_tse_mac_pcs_pma_strx_gx_ena:altera_tse_mac_pcs_pma_strx_gx_ena_inst|altera_tse_top_1000_base_x_strx_gx:top_1000_base_x_strx_gx_inst|altera_tse_top_sgmii_strx_gx:U_SGMII|altera_tse_top_rx_converter:U_RXCV|altera_tse_a_fifo_24:U_DSW|altera_tse_sdpm_altsyncram:U_RAM|altsyncram:altsyncram_component|altsyncram_q2e1:auto_generated|ram_block1a8 cannot have value "old" when different read and write clocks are used. Critical Warning: "mixed_port_feed_through_mode" parameter of RAM atom altera_tse_mac_pcs_pma_gige:altera_tse_mac_pcs_pma_gige_inst|altera_tse_mac_pcs_pma_strx_gx_ena:altera_tse_mac_pcs_pma_strx_gx_ena_inst|altera_tse_top_1000_base_x_strx_gx:top_1000_base_x_strx_gx_inst|altera_tse_top_sgmii_strx_gx:U_SGMII|altera_tse_top_rx_converter:U_RXCV|altera_tse_a_fifo_24:U_DSW|altera_tse_sdpm_altsyncram:U_RAM|altsyncram:altsyncram_component|altsyncram_q2e1:auto_generated|ram_block1a7 cannot have value "old" when different read and write clocks are used.

    您可以安全地忽略警告消息。

    此问题影响所有包含 1000BASE-X/SGMII 的设计 PCS 功能。

    解决方法

    无解决方法。此问题将在将来的版本中修复 三速以太网 MegaCore 功能之一。

    相关产品

    本文适用于 1 产品

    英特尔® 可编程设备