跳转至主要内容
支持知识库

在 SEL 上出现严重错误 面向高性能计算的英特尔® 数据中心模块 (英特尔® DCB for HPC)

内容类型: 错误讯息   |   文章 ID: 000059777   |   上次审核日期: 2022 年 08 月 23 日

说明

SEL 中的重要错误:
SmaRT-CLST 已评定 Stat 报告: Apollo 事件 - 从 PSU 传感器 0x67Y 过渡到临界点

解决方法

  • 出现在调试日志上的错误并非错误,而是表明有轻微的断电,因为英特尔 PSU 旨在对电源信号敏感,并且可以检测到很少的断电。
  • 建议 使用 在线 UPS 而不是线路交互式 UPS。
  • 检查 UPS 的型号/类型。
  • 将 BIOS 更新到最新版本。

其他信息:

调试日志错误;

EventID:0367 Time Stamp:06/04/2020 16:16:43 SensorName:SmaRT & CLST     Sensor Type:OEM Reserved               Description:transition to critical from less severe from PSU sensor 0x66. reports it has been asserted. -Asserted

EventID:0368 Time Stamp:06/04/2020 16:16:43 SensorName:PS1 Status      Sensor Type:Power Supply               Description:reports the power supply's input (AC/DC) has been lost -Asserted

EventID:0369 Time Stamp:06/04/2020 16:16:43 SensorName:SmaRT & CLST     Sensor Type:OEM Reserved               Description:transition to non-critical from more severe from PSU sensor 0x66. reports it has been deasserted. -Asserted

EventID:0370 Time Stamp:06/04/2020 16:16:44 SensorName:SmaRT & CLST     Sensor Type:OEM Reserved               Description:transition to critical from less severe from PSU sensor 0x67. reports it has been asserted. -Asserted

EventID:0371 Time Stamp:06/04/2020 16:16:44 SensorName:Pwr Unit Status    Sensor Type:Power Unit                Description:reports the power unit has suffered a failure -Asserted

EventID:0372 Time Stamp:01/01/1970 00:00:30 SensorName:Pwr Unit Status    Sensor Type:Power Unit                Description:reports the power unit is powered off or being powered down -Asserted

EventID:0373 Time Stamp:01/01/1970 00:00:30 SensorName:Pwr Unit Status    Sensor Type:Power Unit                Description:reports the power unit's AC is lost -Asserted

EventID:0374 Time Stamp:01/01/1970 00:00:30 SensorName:P1 Status       Sensor Type:Processor                 Description:reports the processor's presence has been detected -Asserted

EventID:0375 Time Stamp:01/01/1970 00:00:30 SensorName:P2 Status       Sensor Type:Processor                 Description:reports the processor's presence has been detected -Asserted

EventID:0376 Time Stamp:01/01/1970 00:00:31 SensorName:Pwr Unit Status    Sensor Type:Power Unit                Description:reports the power unit's AC is lost -Deasserted

EventID:0377 Time Stamp:08/24/2030 16:19:43 SensorName:P1 Status       Sensor Type:Processor                 Description:reports the processor's presence has been detected -Asserted

EventID:0378 Time Stamp:08/24/2030 16:19:43 SensorName:P2 Status       Sensor Type:Processor                 Description:reports the processor's presence has been detected -Asserted

 

特别 提款 权:

0628 - RID:0274 TS:06/12/2020 19:25:46 SN:unnamed sensor 0x00 (no SDR) ST:OS Boot ED:C: boot completed ET:Asserted EC:OK

0629 - RID:0275 TS:06/12/2020 19:25:46 SN:unnamed sensor 0xB4 (no SDR) ST:Unknown ED:OEM ET:Deasserted EC:OK

0630 - RID:0276 TS:06/13/2020 11:35:24 SN:unnamed sensor 0x00 (no SDR) ST:OS Stop ED:OS Graceful Shutdown ET:Asserted EC:OK

0631 - RID:0277 TS:06/13/2020 11:35:24 SN:unnamed sensor 0x00 (no SDR) ST:Unknown ED:Unknown ET:Asserted EC:OK

0632 - RID:0278 TS:06/13/2020 11:35:24 SN:unnamed sensor 0x00 (no SDR) ST:OS Stop ED:OS Graceful Shutdown ET:Asserted EC:OK
 

相关产品

本文适用于 3 产品。

免责声明

本页面上的内容是原始英文内容的人工翻译与计算机翻译的组合。我们提供此内容是为了您的便利并且仅供参考,未必完整或准确。如果本页面的英文版与翻译版之间存在任何冲突,应以英文版为准。 查看此页面的英语版本。